
Add to Cart
CAT6 UTP CABLE 23AWG Extend to 550MHz CMP PVC High Speed Lan Cable 1000FT
Quick Detail:
· Bare solid copper conductor
· 250MHz
· Jacket PVC, 60P, -20~75℃
· Rate temperature:60℃ 75℃
· InstallationTemperature: -30℃-+50℃
· CompliestoANSI/TIA-568-B.2&IS0/EC11801
· CE, RoHS, TUV, UL compliant, CPR, ETL, RCM, ISO9001
Description:
>Cat6 UTP Cable Provide 250MHz bandwidth within a distance of 90 meters. The typical application rate is 1000Mbps.
>The bandwidth of this Cat6 cable can reach 550MHz. A bandwidth of 550MHz can support high-speed data transmission and is suitable for application scenarios with high requirements for network speed.
>The Cat6 Cable selects high-quality oxygen-free copper as the transmission conductor. At the same time, it adopts the design of a central cross-shaped PE skeleton to separate four individual pairs. The electrical transmission performance is reliable and excellent, reaching and exceeding the Category 6 system indicators, providing abundant margin support for the system link. It is convenient and fast for construction and laying.
>CMP cables adopt special materials and structural designs and have extremely high flame retardant performance.
Specifications:
Product Description: CAT6 UTP Cable 4 X 2 X 23AWG (CMP) | ||||||
Rev.: A | ECN Description: | |||||
Construction Item Description | Electrical Property | |||||
Conductor |
Material | Bare Solid Copper(elongation: 19-24%) | Conductor Resistance at 20°C | ≤ 9.5 Ω / 100m | ||
OD | 23AWG | Resistance unbalance within a pair | ≤ 2% | |||
Insulation |
Material | FEP DAIKIN NP-101 E79842 | Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V |
>1500 MΩ / 100m | ||
OD | 1.01 ± 0.01 mm | Mutual capacitance | 5600 pF / 100m MAX | |||
Average THK | 0.22 mm | Capacitance unbalance pair to ground at 800Hz or 1 kHz | ≤ 160 pF / 100m | |||
Color | 1p: white + 2 blue stripes & blue | Characteristic impedance at 100MHz | 100 ±15 Ω | |||
2p: white + 2 orange stripes & orange | Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or 0.7 KV AC for 1 min |
No breakdown | ||||
3p: white + 2 green stripes & green | Mechanical Property | |||||
4p: white + 2 brown stripes & brown |
insulation | elongation before aging | ≥ 250% | |||
Pair Twist |
Lay & Direction | 1p: S=18.5 mm (26%) | tensile strength before aging | ≥20 MPa | ||
2p: S=15.5 mm (21%) | elongation after aging | ≥ 200 % | ||||
3p: S=20.5 mm (30%) | tensile strength after aging | ≥16 MPa | ||||
4p: S=14.0 mm (19%) |
jacket | elongation before aging | ≥ 150 % | |||
OD | / | tensile strength before aging | ≥ 13.5 MPa | |||
Inner Assemble | Lay | S=90±5 mm | elongation after aging | ≥ 125 % | ||
Direction | according to the drawing | tensile strength after aging | ≥ 12.5 MPa | |||
Filler | cross member 4.8X4.8X0.5mmT | Packing | ||||
OD | / | Inner Box | NA | |||
Filler | Material | Ripcord | Master Carton | NA | ||
Construction | 300D |
| ||||
Outside Shield | Shield | / | ||||
Construction | / | |||||
Material | / | |||||
Coverage | / | |||||
Jacket |
Material | PVC, MSC 1080 NAT E107947 | ||||
Hardness | 81 ±3 | |||||
OD | 6.0 ± 0.2 | |||||
Average THK | 0.55~0.60 | |||||
Color | blue | |||||
Marking Color | black | |||||
Marking | according to the customer's requirements |
Electrical Properties | ||
Conductor Resistance at 20°C | UL 444 & CSA C22.2 No. 214 | ≤ 9.5 Ω / 100m |
Resistance unbalance within a pair | ≤ 2% | |
Dielectric Strength Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min |
No breakdown | |
Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V | >1500 MΩ / 100m | |
Mutual capacitance | 5600pF / 100m MAX | |
Capacitance unbalance pair to ground at 800Hz or 1 kHz | ≤ 160 pF / 100m | |
Characteristic impedance at 100MHz | 100 ± 15 Ω | |
Spark Test | 2000 ± 250VOC |
Transmission Properties | |||||||||
CAT 6 UTP Cable | |||||||||
No. |
Frequency |
Attenuation (Max) | Propagation Delay (MAX) | Propagation Delay Skew (MAX) |
Return Loss (Min) |
NEXT (Min) |
PS NEXT (Min) |
EL-FEXT (Min) |
PS EL-FEXT (Min) |
MHz | dB/100m | ns/100m | ns/100m | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | |
1 | 4 | 3.78 | 552 | 45 | 23.01 | 66.27 | 63.27 | 55.96 | 52.96 |
2 | 8 | 5.32 | 546.73 | 45 | 24.52 | 61.75 | 58.75 | 49.94 | 46.94 |
3 | 10 | 5.95 | 545.38 | 45 | 25 | 60.3 | 57.3 | 48 | 45 |
4 | 16 | 7.55 | 543 | 45 | 25 | 57.24 | 54.24 | 43.92 | 40.92 |
5 | 20 | 8.47 | 542.05 | 45 | 25 | 55.78 | 52.78 | 41.98 | 38.98 |
6 | 25 | 9.51 | 541.2 | 45 | 24.32 | 54.33 | 51.33 | 40.04 | 37.04 |
7 | 31.25 | 10.67 | 540.44 | 45 | 23.64 | 52.88 | 49.88 | 38.1 | 35.1 |
8 | 50 | 13.66 | 539.09 | 45 | 22.21 | 49.82 | 46.82 | 34.02 | 31.02 |
9 | 62.5 | 15.38 | 538.55 | 45 | 21.54 | 48.36 | 45.36 | 32.08 | 29.08 |
10 | 100 | 19.8 | 537.6 | 45 | 20.11 | 45.3 | 42.3 | 28 | 25 |
11 | 125 | 22.36 | 537.22 | 45 | 19.43 | 43.85 | 40.85 | 26.06 | 23.06 |
12 | 200 | 28.98 | 536.55 | 45 | 18 | 40.78 | 37.78 | 21.98 | 18.98 |
13 | 250 | 32.85 | 536.28 | 45 | 17.32 | 39.33 | 36.33 | 20.04 | 17.04 |
14 | *300 | 31.45 | 537.22 | 45 | 18.11 | 40.78 | 37.78 | 21.98 | 18.98 |
15 | *350 | 33.76 | 537.6 | 45 | 19.54 | 42.58 | 40.85 | 23.45 | 23.06 |
16 | *400 | 32.85 | 528.15 | 45 | 18 | 39.36 | 39.36 | 26.06 | 24.45 |
17 | *450 | 34.15 | 534.23 | 45 | 19.36 | 41.28 | 37.78 | 24.45 | 19.36 |
18 | *500 | 35.76 | 538.36 | 45 | 17.32 | 43.85 | 36.33 | 21.98 | 18.98 |
19 | *550 | 34.12 | 539.09 | 45 | 19.43 | 40.06 | 40.3 | 20.04 | 17 |
Remarks: * are the reference values. |
Notices:
1. Open the packaging, check the products carefully, and take them gently.
2. Please strictly follow the wiring standards during construction, and do not tie or excessively bend the network cables.
3. When making RJ45 network cable connectors, please follow the T568B or T568A standards to ensure the correct wire sequence and avoid problems such as disconnected lines or unstable network connections.
4.It is best to use a single network cable at a distance of no more than 100 meters to ensure optimal transmission performance.
5. Ensure that the shielded network cable is grounded during installation.
Applications:
1. This Cat6 UTP CMP cable, due to its high level of fire resistance and flame retardancy, is generally used in specific environments to ensure that the cable can effectively prevent the spread of flames, reduce the generation of smoke and toxic gases, and ensure personnel evacuation and fire safety in specific environments (such as pressure ventilation ducts).
2. This type of CMP Cat6 cable is typically installed in air return pressurization systems used in ventilation ducts or air handling equipment, and is recognized and adopted by Canada and the United States.
3. CMP Cat6 cable is Plenum grade cable, suitable for air circulation spaces such as between ceilings and floors of buildings. This type of network cable is made of non flammable materials and has extremely high flame retardant properties. When burned, it will produce a very small amount of smoke and non-toxic gas. Due to its excellent flame retardant performance, CMP grade Ethernet cables are usually installed in air return and pressurization systems used in ventilation ducts and air handling equipment, especially in places with extremely high safety performance requirements such as computer rooms.
FAQ
UL/CE/RoHS/ETL/CPR Certificate Lan cable Cat6 U/UTP 23AWG Extend to 550MHz CMP PVC Bare Solid Copper
Q1. Can I order samples of Lan cables?
A: Yes, we welcome sample order to test and check quality.
Q2. What about the lead time?
A: 3-5 days for Sample preparing ,15-45 days for mass production.
Q3. Do you have a minimum order quantity limit for network cable orders?
A: Low MOQ, 1pc for sample checking is available.
Q4. How do you ship the goods and how long does it take to arrive?
A: We usually ship by sea, which usually takes about 7 days to arrive.
Q5. How to proceed an order for network cable?
A: Firstly let us know your requirements or application.
Secondly We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.
Q6.Is it OK to print my logo on network cable product?
A: Yes. Please inform us formally before our production.
Q7: Do you offer guarantee for the products?
A: Yes, we offer 10 years warranty to our products.
Q8: How to deal with the faulty?
A: Firstly, Our products are produced in strict quality control system and the defective rate will be less than 0.2%.
Secondly, for individual defective products, we will remedy them as soon as possible and send them to you, or we can discuss solutions based on the actual situation to achieve 100% satisfaction for you.