Contact Now
Integrity Cable Co., Limited
Visit Website
City:shenzhen
Country/Region:china
Contact Person:Mrtony
Contact Now

1000FT UTP CAT6 Cable 23AWG CMX Plenum PVC High Speed Network Cable

Ask Latest Price
Video Channel
Place of Origin :shenzhen
Brand Name :ITI-LINK
Certification :UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
Model Number :ITI-CT6U-003
MOQ :1000pcs
Packaging Details :Color Box+Packing Box 36*36*21cm
Delivery Time :15-45Days
Payment Terms :T/T
Supply Ability :2000pcs/day
Color :GRAY
Data Transfer Rate :1000 Mbps
Length :1000 ft
Frequency :250 MHz
Application :100Base-TX/100Base-T4/100VG-AnyLan/ATM
Cable Type :U/UTP
Conductor Size :23 AWG
Certifications :UL, ETL, RCM, CPR, CSA
Conductor aMaterial :Bare Copper
flame retardant grade :CMX
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Cat6 UTP Cable 23AWG CMX Plenum PVC High Speed Network Cable 1000FT

Quick Detail:

· Bare solid copper conductor

· 250MHz

· Jacket PVC, CMX 60P, -20~75℃

· Rate temperature:60℃ 75℃

· InstallationTemperature: -30℃-+50℃

· CompliestoANSI/TIA-568-B.2&IS0/EC11801

· CE, RoHS, TUV, UL compliant, CPR, ETL, RCM, ISO9001

Description:

1. Provide 250MHz bandwidth within a distance of 90 meters. The typical application rate is 1000Mbps.

2. The Cat6 CMX-rated cable can be used for general-purpose indoor wiring and has certain flame retardant properties.

3. The product selects high-quality oxygen-free copper as the transmission conductor. At the same time, it adopts the design of a central cross-shaped PE skeleton to separate four individual pairs. The electrical transmission performance is reliable and excellent, reaching and exceeding the Category 6 system indicators, providing abundant margin support for the system link. It is convenient and fast for construction and laying.

4.This Category 6 cable not only meets the CMX flame retardant level, but also meets the performance standards of Category 6 network cables. Six types of network cables can support high-speed data transmission, with wide bandwidth, low attenuation, and strong anti-interference ability, meeting the needs of modern network communication. Specifically, the transmission frequency, attenuation crosstalk ratio (ACR), insertion loss, and other key performance indicators of the six types of network cables meet or exceed relevant international standards.

Specifications:

Product Description: Cat 6 CMX UTP CABLE 4 X 2 X 23AWG
Rev.: A ECN Description:
Construction Item Description Electrical Property

Conductor

Material

Bare Solid Copper(elongation:

19-24%)

Conductor Resistance at 20°C ≤ 9.5 Ω / 100m
OD 23 AWG Resistance unbalance within a pair ≤ 2%

Insulation

Material

HDPE 8303

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

>1500 MΩ / 100m

OD 1.01 ± 0.01 mm Mutual capacitance 5600 pF / 100m MAX
Average THK 0.22 mm Capacitance unbalance pair to ground at 800Hz or 1 kHz ≤ 160 pF / 100m

Color

1p: white + 2 blue stripes & blue Characteristic impedance at 100MHz 100 ±15 Ω

2p: white + 2 orange stripes &

orange

Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

0.7 KV AC for 1 min

No breakdown

3p: white + 2 green stripes & green Mechanical Property
4p: white + 2 brown stripes & brown

insulation

elongation before aging ≥ 300%

Pair Twist

Lay & Direction

1p: S=18.5 mm (26%) tensile strength before aging ≥12 MPa
2p: S=15.5 mm (21%) elongation after aging ≥ 150 %
3p: S=20.5 mm (30%) tensile strength after aging ≥10.5 MPa
4p: S=14.0 mm (19%)

jacket

elongation before aging ≥ 150 %
OD / tensile strength before aging ≥ 13.5 MPa

Inner Assemble

Lay S=90±5 mm elongation after aging ≥ 125 %
Direction according to the drawing tensile strength after aging ≥ 12.5 MPa
Filler cross member 4.5X4.5X0.4mmT Packing
OD / Inner Box NA
Filler Material Ripcord Master Carton NA
Construction 300D

Outside Shield

Shield /
Construction /
Material /
Coverage /

Jacket

Material PVC, Rated 60 or 75
Hardness 81 ±3
OD 6.0 ± 0.2
Average THK 0.55~0.60

Color

according to the customer's requirements

Marking Color

according to the customer's

requirements

Marking

according to the customer's

requirements

Electrical Properties
Conductor Resistance at 20°C

UL 444 & CSA C22.2

No. 214

≤ 9.5 Ω / 100m
Resistance unbalance within a pair ≤ 2%

Dielectric Strength

Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min

No breakdown

Insulation Resistance at 20°C after 2min of electrification under a DC voltage

between 100 & 500V

>1500 MΩ / 100m
Mutual capacitance 5600pF / 100m MAX
Capacitance unbalance pair to ground at 800Hz or 1 kHz ≤ 160 pF / 100m
Characteristic impedance at 100MHz 100 ± 15 Ω
Spark Test 2000 ± 250VOC

Transmission Properties
CAT 6 CMX CABLE

No.

Frequency

Attenuation (Max)

Propagation Delay (MAX) Propagation Delay Skew (MAX)

Return Loss (Min)

NEXT (Min)

PS NEXT (Min)

EL-FEXT (Min)

PS EL-FEXT (Min)

MHz dB/100m ns/100m ns/100m dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m)
1 4 3.78 552 45 23.01 66.27 63.27 55.96 52.96
2 8 5.32 546.73 45 24.52 61.75 58.75 49.94 46.94
3 10 5.95 545.38 45 25 60.3 57.3 48 45
4 16 7.55 543 45 25 57.24 54.24 43.92 40.92
5 20 8.47 542.05 45 25 55.78 52.78 41.98 38.98
6 25 9.51 541.2 45 24.32 54.33 51.33 40.04 37.04
7 31.25 10.67 540.44 45 23.64 52.88 49.88 38.1 35.1
8 50 13.66 539.09 45 22.21 49.82 46.82 34.02 31.02
9 62.5 15.38 538.55 45 21.54 48.36 45.36 32.08 29.08
10 100 19.8 537.6 45 20.11 45.3 42.3 28 25
11 125 22.36 537.22 45 19.43 43.85 40.85 26.06 23.06
12 200 28.98 536.55 45 18 40.78 37.78 21.98 18.98
13 250 32.85 536.28 45 17.32 39.33 36.33 20.04 17.04
14
15
16
17
18
Remarks: * are the reference values.

Notices:

1. Open the packaging, check the products carefully, and take them gently.

2. Please strictly follow the wiring standards during construction, and do not tie or excessively bend the network cables.

3. When making RJ45 network cable connectors, please follow the T568B or T568A standards to ensure the correct wire sequence and avoid problems such as disconnected lines or unstable network connections.

4.It is best to use a single network cable at a distance of no more than 100 meters to ensure optimal transmission performance.

5. Ensure that the shielded network cable is grounded during installation.

Applications:

Due to its high flame retardancy, excellent shielding effect, and Cat6 performance standards, CMX flame retardant Cat 6 network cables are widely used in applications that require secure and stable data transmission, such as data centers, hospitals, industrial automation, and other fields. In the data center, this cable provides high-speed and stable network connections for servers and storage devices, ensuring real-time transmission and processing of data. In hospitals, it provides reliable network connections for medical equipment, ensuring real-time updates and sharing of medical information. In the field of industrial automation, it provides stable communication support for industrial equipment to ensure the smooth operation of production lines.

1000FT UTP CAT6 Cable 23AWG CMX Plenum PVC High Speed Network Cable

FAQ

UL/CE/RoHS/ETL/CPR Certificate Lan cable Cat6 U / UTP 23AWG Extend To 550MHz CMX PVC Bare Solid Copper

Q1. Can I order samples of Lan cables?

A: Yes, we welcome sample order to test and check quality.

Q2. What about the lead time?

A: 3-5 days for Sample preparing ,15-45 days for mass production.

Q3. Do you have a minimum order quantity limit for network cable orders?

A: Low MOQ, 1pc for sample checking is available.

Q4. How do you ship the goods and how long does it take to arrive?

A: We usually ship by sea, which usually takes about 7 days to arrive.

Q5. How to proceed an order for network cable?

A: Firstly let us know your requirements or application.

1. We quote according to your requirements or our suggestions.

2. customer confirms the samples and places deposit for formal order.

3. We arrange the production.

Q6.Is it OK to print my logo on network cable product?

A: Yes. Please inform us formally before our production.

Q7: How to deal with the faulty?

A: Firstly, Our products are produced in strict quality control system and the defective rate will be less than 0.2%.

Inquiry Cart 0